Repository of Research and Investigative Information

Repository of Research and Investigative Information

Baqiyatallah University of Medical Sciences

Ordered Mesoporous Carbon/Poly (2-Hydroxyethyl Methacrylate/Ag Nanoparticle Composite Modified Glassy Carbon Electrode; an Amplified Sensor for Simultaneous Determination of Acetaminophen and Domperidone

(2018) Ordered Mesoporous Carbon/Poly (2-Hydroxyethyl Methacrylate/Ag Nanoparticle Composite Modified Glassy Carbon Electrode; an Amplified Sensor for Simultaneous Determination of Acetaminophen and Domperidone. Electroanalysis. pp. 2454-2461. ISSN 1040-0397

[img] Text
Ordered Mesoporous CarboPoly (2-Hydroxyethyl MethacrylateAg Nanoparticle Composite Modified Glassy Carbon Electrode; an Amplified Sensor for Simultaneous Determination of Acetaminophen and Domperidone.pdf

Download (1MB)

Official URL: http://apps.webofknowledge.com/InboundService.do?F...

Abstract

In this study, we describe a modification of a glassy carbon electrode with an ordered mesoporous carbon (OMC)/poly (2-hydroxyethyl methacrylate) (PHEMA)/Ag nanoparticle composite (GCE/AgNPs-PHEMA-CMK-1) done for the first time and the application of a proposed sensor for the simultaneous determination of acetaminophen (AC) and domperidone (DO). The transmission electron microscopy (TEM), fourier-transform infrared spectroscopy (FT-IR), electrochemical impedance spectroscopy (EIS), UV-vis spectroscopy, and X-ray powder diffraction (XRD) methods were used for the analysis of the synthesized nanocomposite. The GCE/AgNPs-PHEMA-CMK-1 showed good catalytic activity for the electro-oxidation of acetaminophen and domperidone in the buffer solution. The pH investigation showed that acetaminophen and domperidone electro-oxidation is relative to the pH value of the solution. The maximum oxidation process occurred at pH=7.0 and pH=8.0 for acetaminophen and domperidone, respectively, on the surface of the GCE/AgNPs-PHEMA-CMK-1. The GCE/AgNPs-PHEMA-CMK-1 showed a linear range between 0.015-7.5M and 0.03-10.8M for acetaminophen and domperidone, respectively. The GCE/AgNPs-PHEMA-CMK-1 showed detection limits of 0.005 and 0.01M for acetaminophen and domperidone, respectively, by the differential pulse voltammetry (DPV) method. Finally, the GCE/AgNPs-PHEMA-CMK-1 was suggested as a highly powerful tool for the analysis of acetaminophen and domperidone in real samples.

Item Type: Article
Keywords: Ordered mesoporous carbon Acetaminophen Domperidone Ag nanoparticle Sensor electrochemical sensor raloxifene hydrochloride sensitive determination hplc analysis nanocomposite paracetamol nanotubes biosensor acid Chemistry Electrochemistry
Divisions:
Page Range: pp. 2454-2461
Journal or Publication Title: Electroanalysis
Journal Index: ISI
Volume: 30
Number: 10
Identification Number: https://doi.org/10.1002/elan.201800068
ISSN: 1040-0397
Depositing User: مهندس مهدی شریفی
URI: http://eprints.bmsu.ac.ir/id/eprint/3601

Actions (login required)

View Item View Item