Fabrication of a Novel Highly Sensitive and Selective Immunosensor for Botulinum Neurotoxin Serotype A Based on an Effective Platform of Electrosynthesized Gold Nanodendrites/Chitosan Nanoparticles

(2017) Fabrication of a Novel Highly Sensitive and Selective Immunosensor for Botulinum Neurotoxin Serotype A Based on an Effective Platform of Electrosynthesized Gold Nanodendrites/Chitosan Nanoparticles. Sensors. p. 13. ISSN 1424-8220

[img] Text
Fabrication of a Novel Highly Sensitive and Selective Immunosensor for Botulinum Neurotoxin Serotype A Based on an Effective Platform of Electrosynthesized Gold NanodendritesChitosan Nanoparticles.pdf

Download (2MB)

Official URL: http://apps.webofknowledge.com/InboundService.do?F...

Abstract

In this work, a novel nanocomposite consisting of electrosynthesized gold nanodendrites and chitosan nanoparticles (AuNDs/CSNPs) has been prepared to fabricate an impedimetric immunosensor based on a screen printed carbon electrode (SPCE) for the rapid and sensitive immunoassay of botulinum neurotoxin A (BoNT/A). BoNT/A polyclonal antibody was immobilized on the nanocomposite-modified SPCE for the signal amplification. The structure of the prepared nanocomposite was investigated by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The charge transfer resistance (RCT) changes were used to detect BoNT/A as the specific immuno-interactions at the immunosensor surface that efficiently limited the electron transfer of Fe(CN)(6)(3-/4-) as a redox probe at pH = 7.4. A linear relationship was observed between the Delta R-CT and the concentration logarithm of BoNT/A within the range of 0.2 to 230 pg.mL(-1) with a detection limit (S/N = 3) of 0.15 pg.mL(-1). The practical applicability of the proposed sensor was examined by evaluating the detection of BoNT/A in milk and serum samples with satisfactory recoveries. Therefore, the prepared immunosensor holds great promise for the fast, simple and sensitive detection of BoNT/A in various real samples.

Item Type: Article
Keywords: label-free immunosensor botulinum neurotoxin biosensors gold nanodendrites chitosan nanoparticles screen printed carbon electrode chitosan nanoparticles electrochemical immunosensor ultrasensitive detection delivery systems ionic gelation label-free assay electrodeposition antibodies substrate Chemistry Engineering Instruments & Instrumentation