Repository of Research and Investigative Information

Repository of Research and Investigative Information

Baqiyatallah University of Medical Sciences

Long-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder

(2013) Long-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder. Iranian Journal of Pediatrics. pp. 411-416. ISSN 2008-2142

[img] Text
Long-term results of transcatheter closure of patent ductus arteriosus in infants using amplatzer duct occluder..pdf

Download (741kB)

Official URL: http://apps.webofknowledge.com/InboundService.do?F...

Abstract

Objective: Patent ductus arteriosus (PDA) is one of the most frequently seen congenital heart diseases. Its closure is recommended because of the risk of infective endocardis, as well as morbidity and mortality in the long. The aim of this study was to assess the long term results of the transcatheter closure of PDA in infants using amplatzer duct occlude (ADO). Methods: From May 2004 to September 2011, forty eight infants underwent transcatheter closure of PDA. A lateral or right anterior oblique view aortogram was done to locate PDA and to measure its size. Before discharge, repeat aortogram was performed to evaluate eventual residual shunt and to confirm the appropriate deployment of the ADO. Follow up evaluations were done with transthoracic echocardiography at discharge, 1 month, 6 months, 12 months and yearly thereafter. Findings: The mean age of patients at procedure was 9.18 +/- 2.32 (range 3 to 12) months, mean weight 6.73 +/- 1.16 (range 4.5 to 10.1) kg. The PDA occluded completely in 20 out of the 48 patients. Twenty four patients had trivial or mild shunt and two patients had moderate residual shunt which disappeared in one patient within 24 hours and other patient with moderate shunt in 1 month. One patient (age 8 months) had mild LPA stenosis. The device emobolization occurred in two patients, immediately after the procedure in one and during night in the other patient Conclusion: The long term results suggested that transcatheter closure of PDA using Amplatzer duct occluder is a safe and effective treatment in infants less than 1 year of age with minimal complications.

Item Type: Article
Keywords: Patent Ductus Arteriosus Transcatheter Closure Congenital Heart Defect occlusion device catheter closure moderate experience immediate safety Pediatrics
Divisions:
Page Range: pp. 411-416
Journal or Publication Title: Iranian Journal of Pediatrics
Journal Index: ISI
Volume: 23
Number: 4
ISSN: 2008-2142
Depositing User: مهندس مهدی شریفی
URI: http://eprints.bmsu.ac.ir/id/eprint/5996

Actions (login required)

View Item View Item