Repository of Research and Investigative Information

Repository of Research and Investigative Information

Baqiyatallah University of Medical Sciences

A fluorescence Nano-biosensors immobilization on Iron (MNPs) and gold (AuNPs) nanoparticles for detection of Shigella spp

(2019) A fluorescence Nano-biosensors immobilization on Iron (MNPs) and gold (AuNPs) nanoparticles for detection of Shigella spp. Materials Science & Engineering C-Materials for Biological Applications. p. 9. ISSN 0928-4931

[img] Text
A fluorescence Nano-biosensors immobilization on Iron (MNPs) and gold (AuNPs) nanoparticles for detection of Shigella spp.pdf

Download (7MB)

Official URL: http://apps.webofknowledge.com/InboundService.do?F...

Abstract

The highly sensitive and specificity detection are very important in diagnosis of foodborne pathogens and prevention of spread diseases. Therefore, in the present study, a highly sensitive fluorescence Nano-biosensors was designed for detection of Shigella species. For achieved this purpose, DNA probes and gold nanoparticles (AuNPs) were designed and synthesized, respectively. Then, two DNA probes as signal reporter were immobilized on surface of AuNPs. On the other hand, Iron nanoparticles (MNPs) were synthesized and modified with SMCC (Sulfosuccinimidyl 4-Nmaleimidomethyl cyclohexane-1- carboxylate). The 3th DNA probe was immobilized on surface of MNPs for separation of target DNA. The MNP-DNA probe and DNA probe-AuNP-fluorescence DNA probe were added to target DNA. The MNP- DNA probe-target DNA-DNA probe-AuNP-fluorescence DNA probe complex was isolated by a magnet. The fluorescence DNA probe was released on surface of AuNPs and the fluorescence intensity was read by fluorescence spectrophotometry. Sensitivity and specificity of designed Nano-biosensor was determined. The results showed that the fluorescence intensity was increased with increasing of target DNA concentration. Linear related between target DNA and fluorescence intensity was observed in 2.3 x 10(2) up to 2.3 x 10(7) CFU mL(-1). The linear equation and regression were Y = 1.8 X + 23.4 and R-2 0.9953. Limit of detection (LOD) were determined 90 CFUmL(-1). The specificity of Nano-biosensor in present of other bacteria was confirmed.

Item Type: Article
Keywords: Fluorescence biosensor Shigella Spa gene MNPs AuNPs real-time pcr ultrasensitive detection sensitive detection rapid detection multiplex pcr salmonella campylobacter coli food Materials Science
Divisions:
Page Range: p. 9
Journal or Publication Title: Materials Science & Engineering C-Materials for Biological Applications
Journal Index: ISI
Volume: 105
Identification Number: https://doi.org/10.1016/j.msec.2019.110113
ISSN: 0928-4931
Depositing User: مهندس مهدی شریفی
URI: http://eprints.bmsu.ac.ir/id/eprint/2293

Actions (login required)

View Item View Item