(2018) Spectrophotometric, colorimetric and visually detection of Pseudomonas aeruginosa ETA gene based gold nanoparticles DNA probe and endonuclease enzyme. Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy. pp. 421-429. ISSN 1386-1425
Text
Spectrophotometric, colorimetric and visually detection of Pseudomonas aeruginosa ETA gene based gold nanoparticles DNA probe and endonuclease enzyme.pdf Download (2MB) |
Abstract
Colorimetric DNA detection is preferred over other methods for clinical molecular diagnosis because it does not require expensive equipment. In the present study, the colorimetric method based on gold nanopartides (GNPs) and endonuclease enzyme was used for the detection of P. aeruginosa ETA gene. Firstly, the primers and probe for P. aeruginosa exotoxin A (ETA) gene were designed and checked for specificity by the PCR method. Then, GNPs were synthesized using the citrate reduction method and conjugated with the prepared probe to develop the new nano-biosensor. Next, the extracted target DNA of the bacteria was added to GNP-probe complex to check its efficacy for P. aeruginosa ETA gene diagnosis. A decrease in absorbance was seen when GNP-probe-target DNA cleaved into the small fragments of BamHI endonuclease due to the weakened electrostatic interaction between GNPs and the shortened DNA. The right shift of the absorbance peak from 530 to 562 nm occurred after adding the endonuclease. It was measured using a UV-VIS absorption spectroscopy that indicates the existence of the P. aeruginosa ETA gene. Sensitivity was determined in the presence of different concentrations of target DNA of P. aeruginosa. The results obtained from the optimized conditions showed that the absorbance value has linear correlation with concentration of target DNA (R: 0.9850) in the range of 10-50 ng mL(-1) with the limit detection of 9.899 ng mL(-1). Thus, the specificity of the new method for detection of P. aeruginosa was established in comparison with other bacteria. Additionally, the designed assay was quantitatively applied to detect the P. aeruginosa ETA gene from 10(3) to 10(8) CFU mL(-1) in real samples with a detection limit of 320 CFU (C) 2018 Elsevier B.V. All rights reserved.
Item Type: | Article |
---|---|
Keywords: | Pseudomonas aeruginosa Colorimetric assay ETA gene Gold nanoparticles Endonuclease salmonella spp. amplification pcr samples Spectroscopy |
Divisions: | |
Page Range: | pp. 421-429 |
Journal or Publication Title: | Spectrochimica Acta Part a-Molecular and Biomolecular Spectroscopy |
Journal Index: | ISI |
Volume: | 199 |
Identification Number: | https://doi.org/10.1016/j.saa.2018.03.056 |
ISSN: | 1386-1425 |
Depositing User: | مهندس مهدی شریفی |
URI: | http://eprints.bmsu.ac.ir/id/eprint/3740 |
Actions (login required)
View Item |