Biomechanical Stress Distribution on Fixation Screws Used in Bilateral Sagittal Split Ramus Osteotomy: Assessment of 9 Methods via Finite Element Method

(2010) Biomechanical Stress Distribution on Fixation Screws Used in Bilateral Sagittal Split Ramus Osteotomy: Assessment of 9 Methods via Finite Element Method. Journal of Oral and Maxillofacial Surgery. pp. 2765-2769. ISSN 0278-2391

Full text not available from this repository.

Official URL: http://apps.webofknowledge.com/InboundService.do?F...

Abstract

Purpose: The aim of this study was to assess the biomechanical stress tolerance of screws used in 9 fixation methods after bilateral sagittal split ramus osteotomy to determine which configuration leads to lesser force load on the cortical bone at fixation points. Materials and Methods: A 3-dimensional computerized model of a human mandible with posterior teeth was generated. The bilateral sagittal split ramus osteotomy was virtually performed on this model. The separated model was assembled with 9 fixation methods: single screw, 2 screws one behind the other, 2 screws one below the other, 3 screws in an L configuration, 3 screws in an inverted backward L configuration, miniplate with 2 screws, miniplate with 4 screws, 2 parallel plates (upper + lower border), and square miniplate with 4 screws. Then, 75-, 135-, and 600-N vertical loads were applied on the posterior teeth of these models. The stress distribution on the screw sites on the buccal cortex was measured by the finite element method. Results: In this model all the fixation methods withstood forces between 75 and 135 N. However, the single-screw and the 2-hole miniplate models showed that the stress distributions in the configurations were intolerable when 600 N of posterior force was applied. The results of this study indicated that the inverted backward L configuration with 3 bicortical screws was the most stable. Conclusion: Although this study indicated that the inverted backward L configuration with 3 bicortical screws was the most stable pattern, most of the patterns had adequate stability for clinical applications (mean, 125 N). (c) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:2765-2769, 2010

Item Type: Article
Keywords: internal-fixation advancement surgery stability fracture model Dentistry, Oral Surgery & Medicine
Divisions:
Page Range: pp. 2765-2769
Journal or Publication Title: Journal of Oral and Maxillofacial Surgery
Journal Index: ISI
Volume: 68
Number: 11
Identification Number: https://doi.org/10.1016/j.joms.2010.03.014
ISSN: 0278-2391
Depositing User: مهندس مهدی شریفی
URI: http://eprints.bmsu.ac.ir/id/eprint/6667

Actions (login required)

View Item View Item