Repository of Research and Investigative Information

Repository of Research and Investigative Information

Baqiyatallah University of Medical Sciences

Visual and subjective outcomes following trifocal intraocular lens implantation in Iranian cataractous patients

(2020) Visual and subjective outcomes following trifocal intraocular lens implantation in Iranian cataractous patients. Oman J Ophthalmol. pp. 63-69. ISSN 0974-620X (Print) 0974-620x

Full text not available from this repository.

Official URL: http://www.ncbi.nlm.nih.gov/pubmed/32792800

Abstract

BACKGROUND: The aim of this study was to evaluate visual and refractive outcomes and quality of vision after implantation of the AT LISA tri 839MP intraocular lens (IOL). PATIENTS AND METHODS: This interventional clinical trial comprised 46 cataractous eyes of patients who underwent phacoemulsification with IOL implantation (mean age of 58.08 ± 11.01 years; range: 36-76 years old). Spherical equivalent (SE), uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), corrected intermediate visual acuity (CIVA), uncorrected near visual acuity (UNVA), and corrected near visual acuity (CNVA) were measured 1, 3, and 6 months after surgery. Contrast sensitivity (CS) was measured at 6 months. Subjective quality of vision and presence of dysphotopsia by a short questionnaire were evaluated postoperatively. RESULTS: At 6 months, the mean visual acuity was 0.08 ± 0.11, 0.03 ± 0.08, 0.07 ± 0.09, 0.02 ± 0.08, 0.05 ± 0.09, and 0.02 ± 0.08 LogMAR for UDVA, CDVA, UIVA, CIVA, UNVA, and CNVA, respectively. The mean values of SE were - 0.4728 ± 0.32D. These variables improved over time, yet significant changes were detected in UDVA (P = 0.009) and SE (P = 0.0001). The mean CS value was 1.74 ± 0.08. The mean scores (0 = no symptoms; 100 = strong symptoms/unable to perform activities) for glare and halos were 7.07 ± 0.22 and 8.70 ± 0.23, respectively. These items were reduced over time. Patients' level of satisfaction mean score for performing activities was 96.66. CONCLUSIONS: The AT LISA tri 839MP IOL provides excellent uncorrected distance, intermediate and near vision, and CS. This IOL showed a minimal level of photic phenomena and a high level of patient satisfaction.

Item Type: Article
Keywords: Contrast sensitivity intraocular lens satisfaction trifocal
Page Range: pp. 63-69
Journal or Publication Title: Oman J Ophthalmol
Journal Index: Pubmed
Volume: 13
Number: 2
Identification Number: https://doi.org/10.4103/ojo.OJO₁₀₇₂₀₁₉
ISSN: 0974-620X (Print) 0974-620x
Depositing User: مهندس مهدی شریفی
URI: http://eprints.bmsu.ac.ir/id/eprint/9108

Actions (login required)

View Item View Item